Service

Heating systems and underfloor heating

Underfloor heating, radiators, boiler rooms and system balancing for heat pump operation.

Underfloor heating pipes laid on insulation before the screed
  • 01

    Underfloor loops designed for a low flow temperature

  • 02

    Radiator replacement sized for a heat pump

  • 03

    Flushing and hydraulic balancing of old systems

  • 04

    Boiler room upgrades and hot water cylinders

What we do

The company started in 2008 with boilers and radiators, so heating systems are our home ground. Today most of this work goes alongside a heat pump installation, but we also do it on its own:

  • underfloor heating in new builds and renovations,
  • replacing radiators and whole radiator systems,
  • rebuilding boiler rooms after a coal or gas boiler is removed,
  • hot water cylinders, buffer tanks, low-loss headers and pump groups,
  • flushing, hydraulic balancing and weather-compensated controls.

Who it is for

  • People building a house who want underfloor heating designed for a heat pump, not by guesswork.
  • Homeowners about to replace their heat source. An old system designed for a coal boiler ran at 70-80°C. A heat pump needs a lower temperature, so some radiators often have to be replaced.
  • Anyone with unevenly heated rooms, such as a cold bathroom and an overheated living room. The system is usually to blame, not the boiler.

How the job runs

  1. Site visit. We check the pipework, radiators, boiler room and where manifolds can go.
  2. Calculations. We calculate room heat losses and size the radiators or underfloor pipe spacing for a specific flow temperature.
  3. Installation. For underfloor heating: insulation, edge strip, PE-RT or PEX pipe at 10-15 cm spacing, a manifold with flow meters. We leave the system under pressure for the screed.
  4. Pressure test and flushing. Every system is pressure tested, and old systems are flushed before connection.
  5. Balancing. We set the flows on the manifolds and radiator valves and configure room thermostats and controls.

What is included

For underfloor heating: insulation with membrane, edge strip, pipe, a manifold in a cabinet, flow meters, a pressure test and a test report. Room thermostats and actuators are priced separately, because with a heat pump they are not always needed in every room. The building contractor lays the screed, and we agree the timing and the curing heat-up programme with them.

What affects the price

  • floor area and the number of loops or radiators,
  • radiator type and size,
  • whether risers and pipes inside walls need replacing,
  • how much of the boiler room has to be rebuilt and old equipment removed,
  • controls: room thermostats, actuators, zoning.

What we do not do

We do not install solid fuel boilers. We rarely fit gas boilers in new systems now, mostly as a second heat source in larger buildings, because Czyste Powietrze no longer subsidises them and new houses usually go for a heat pump. If a gas boiler makes more sense than a heat pump in your case, we will say so during the site visit.

Subsidies

Upgrading the heating and hot water system can be an eligible cost under Czyste Powietrze when it is done together with replacing the heat source. The details depend on the scope of work and the programme's current conditions, which we check on the programme website when preparing the application.

How we work

From site visit to service. One company at every step.

  1. 1. Sizing

    A site visit and a heat-loss calculation. We size the unit for the building, not the floor area.

  2. 2. Subsidy

    We check which programme you qualify for and help you put the application together.

  3. 3. Installation

    Our own crews, usually 2-4 days. Commissioning, heating curve set-up and a walkthrough.

  4. 4. Service

    A check after the first month and the yearly inspections the manufacturer warranty requires.

FAQ

Frequently asked questions

Question not here? Write or call us, we reply within one working day.

Write to us
Underfloor heating or radiators with a heat pump?

Underfloor heating lets the heat pump run at 30-35°C and gives the lowest bills. Radiators can also work well if they are sized for about 45-50°C. In renovated houses we often combine the two: underfloor heating in bathrooms and on the ground floor, radiators upstairs.

Can underfloor heating go into an older house?

Yes, but you need about 8-12 cm of height for insulation, pipes and screed. If you do not have that, low-profile systems exist, but they cost more. Often it is simpler to fit larger radiators.

Why flush the system?

Old systems contain sludge, rust and other deposits. They did not bother a coal boiler, but they clog the filters and heat exchanger of a heat pump. We flush before connecting a new heat source.

What is hydraulic balancing?

Setting the flows so that each radiator and each loop gets the amount of water it needs. Without it some rooms overheat while others stay cold, and you end up raising the temperature of the whole system.

Case studies

Related projects

All projects

Blog